Rego®’s Dielectric second stage regulators are designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads.
Rego® Dielectric second stage regulators are engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. Available in both SAE Flare and F.NPT inlet connection.
Items |
LV004403B36RAD LV4403BD Series 3/8" Size and Male Flare Type Inlet Connection Dielectric Second Stage Regulator Price QUOTE
|
LV004403B1D LV4403BD Series 1/2" Size and Male Flare Type Inlet Connection Dielectric Second Stage Regulator Price QUOTE
|
LV004403B16D LV4403BD Series 1/2" Size and Male Flare Type Inlet Connection Dielectric Second Stage Regulator Price QUOTE
|
LV004403B16RD LV4403BD Series 1/2" Size and Male Flare Type Inlet Connection Dielectric Second Stage Regulator Price QUOTE
|
LV004403B16RABD LV4403BD Series 1/2" Size and Male Flare Type Inlet Connection Dielectric Second Stage Regulator Price QUOTE
|
|||||
Description |
N/A
Rego®’s Dielectric second stage regulators are designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. |
N/A
Designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. |
N/A
Designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. |
N/A
Designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. |
N/A
Designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly. |
|||||
Number of Inlet Connectors | N/A 3 | N/A 1 | N/A 1 | N/A 1 | N/A 1 | |||||
Inlet Connection Size | N/A 3/8 in | N/A 1/2 in | N/A 1/2 in | N/A 1/2 in | N/A 1/2 in | |||||
Inlet Connection Type | N/A Male Flare | |||||||||
Outlet Connection Size | N/A 3/4 in | N/A 1/2 in | N/A 3/4 in | N/A 3/4 in | N/A 3/4 in | |||||
Outlet Connection Type | N/A Female National Pipe Thread (FNPT) | |||||||||
Inlet Material | N/A | N/A Brass | N/A Brass | N/A Brass | N/A Brass | |||||
Orifice Size | N/A 3/16 in | N/A #28 Drill | N/A #28 Drill | N/A #28 Drill | N/A 3/16 in | |||||
Factory Delivery Pressure at 10 Pounds Per Square Inch Gauge (psig) Inlet Pressure | N/A 11 inWc | |||||||||
Pressure Adjustment Range | N/A 9 to 13 inWc | |||||||||
Bonnet Vent Position | N/A Over Inlet | |||||||||
Propane Vapor Capacity1 | N/A 1,000,000 Btu/hr | N/A 935,000 Btu/hr | N/A 935,000 Btu/hr | N/A 935,000 Btu/hr | N/A 1,000,000 Btu/hr | |||||
Pressure Rating | N/A 10 psig | |||||||||
Size | N/A 3/8 in | N/A 1/2 in | N/A | N/A | N/A | |||||
Capacity | N/A 1,000,000 Btu/hr | N/A 935,000 Btu/hr | N/A 935,000 Btu/hr | N/A 935,000 Btu/hr | N/A 1,000,000 Btu/hr | |||||
Material | N/A Die-Cast Zinc | |||||||||
Note |
N/A
Right Angle Design |
N/A | N/A |
N/A
Backmount Design |
N/A
Right Angle with Bracket |
|||||
Vendor Item # | N/A | |||||||||
UNSPSC Code | N/A | |||||||||
|