For efficient transfer of butane, propane, or anhydrous ammonia.
Unit of Measure

Specifications

Capacity

N/A 18 to 50 gpm

Alternate Part Number

N/A H50GL

Compressor Specifications

Number of Cylinders

N/A 2

Displacement

N/A 10.7 in³

Stroke Size

N/A 1.811 in

Bore Size

N/A 1.875 in

Suction Swivel Pipe

N/A 1/2 in

Discharge Swivel Pipe

N/A 1/2 in

Compressor Preset Rotation

N/A 1000 rpm

Engine Preset Rotation

N/A 2800 rpm

General Specifications

A/B Vee Belt Drive

N/A 38 in

Shipping Weight

N/A 70 lb

Engine Specifications

Overhead Valve Power

N/A 4 hp

Compressor Specifications

N/A 5/8 Pint Oil (SAE 40 non-detergent)

General Specifications

N/A
  • 9" x 18" x 11 Gauge Steel Base
  • Expanded Metal Belt Guard
  • Carrying Handle

Engine Specifications

N/A
  • Shaft Lauson Engine
  • Spark Arresting Muffler
  • Shielded Electronic Ignition
  • On/Off Switch

How it Works

How it Works

N/A The suction side of the compressor draws vapor from the applicator tank into the discharge side of the compressor. This causes a pressure drop in the applicator tank. A pressure drop of 5 to 10 PSI will cause liquid to flow from the field nurse tank into the applicator tank. Care should be taken that the applicator tank is not overfilled, as this could cause oil to flow from the compressor crankcase.