Number of Cylinders |
N/A 2 |
Displacement |
N/A 10.7 inĀ³ |
Stroke Size |
N/A 1.811 in |
Bore Size |
N/A 1.875 in |
Suction Swivel Pipe |
N/A 1/2 in |
Discharge Swivel Pipe |
N/A 1/2 in |
Compressor Preset Rotation |
N/A 1000 rpm |
Engine Preset Rotation |
N/A 2800 rpm |
Overhead Valve Power |
N/A 4 hp |
Compressor Specifications |
N/A 5/8 Pint Oil (SAE 40 non-detergent) |
General Specifications |
N/A
|
Engine Specifications |
N/A
|
How it Works |
N/A The suction side of the compressor draws vapor from the applicator tank into the discharge side of the compressor. This causes a pressure drop in the applicator tank. A pressure drop of 5 to 10 PSI will cause liquid to flow from the field nurse tank into the applicator tank. Care should be taken that the applicator tank is not overfilled, as this could cause oil to flow from the compressor crankcase. |