Designed to reduce first stage pressure normally 10 PSIG down to burner pressure, normally 11" w.c. and are ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. engineered to isolate potential electrical current from metallic piping before entering a building. The use of a separate dielectric union is not necessary because the regulator contains a dielectric union as part of the inlet assembly.
Inlet Connection Size |
N/A 3/4 in |
Inlet Connection Type |
N/A Female National Pipe Thread (FNPT) |
Outlet Connection Size |
N/A 3/4 in |
Outlet Connection Type |
N/A Female National Pipe Thread (FNPT) |
Inlet Material |
N/A Brass and Plated Steel |
Orifice Size |
N/A 3/16 in |
Factory Delivery Pressure at 10 Pounds Per Square Inch Gauge (psig) Inlet Pressure |
N/A 11 inWc |
Pressure Adjustment Range |
N/A 9 to 13 inWc |
Bonnet Vent Position |
N/A Over Inlet |
Propane Vapor Capacity1 | N/A 1,000,000 Btu/hr |
Pressure Rating |
N/A 10 psig |
Size |
N/A 3/4 in |
Material |
N/A Die-Cast Zinc |