Print Back
Direct Fired Liquefied Petroleum Gas (LPG) Vaporizers
Unit of Measure
Items Image
40/40
80 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
Price QUOTE
Image
80/40
160 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
Price QUOTE
Image
120/60
240 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
Price QUOTE
320 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
160H
320 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
Price QUOTE
Image
320H
640 Kilogram per Hour (kg/h) Capacity Direct Fired Liquefied Petroleum Gas (LPG) Vaporizer
Price QUOTE
Description N/A
Vaporization Type N/A Direct Fired Feed-Out
Electrical Data N/A None Required
Design Pressure1 N/A 290 psig20.0 barg
Relief Valve Set Point N/A 250 psig17.2 barg
Hydrostatic Pressure N/A 435 psig29.9 barg
Certifications/Industry Standards N/A American Society of Mechanical Engineers (ASME) European Conformity (CE) Pressure Equipment Directive (PED)(DNV) Underwriters' Laboratories (UL) (US and Canada) N/A American Society of Mechanical Engineers (ASME) European Conformity (CE) Pressure Equipment Directive (PED)(DNV) Underwriters' Laboratories (UL) (US and Canada) N/A American Society of Mechanical Engineers (ASME) European Conformity (CE) Pressure Equipment Directive (PED)(DNV) Underwriters' Laboratories (UL) (US and Canada) N/A American Society of Mechanical Engineers (ASME) Underwriters' Laboratories (UL) (US and Canada) N/A American Society of Mechanical Engineers (ASME) Underwriters' Laboratories (UL) (US and Canada)
Liquid Inlet Female National Pipe Thread (FNPT) N/A 3/4 in N/A 3/4 in N/A 3/4 in N/A 3/4 in N/A 2 in
Vapor Outlet Female National Pipe Thread (FNPT) N/A 1 in N/A 1 in N/A 1 in N/A 1 in N/A 2 in
Vaporization Capacity N/A 80 kg/h3.6 MMBtu/hour N/A 160 kg/h7.2 MMBtu/hour N/A 240 kg/h10.9 MMBtu/hour N/A 320 kg/h14.6 MMBtu/hour N/A 640 kg/h29.1 MMBtu/hour
Nominal Vaporization Capacity (United States (US))2 N/A 40 gal/h N/A 80 gal/h N/A 120 gal/h N/A 160 gal/h N/A 320 gal/h
Burner Input N/A 13.0 kcal/h51.3 Btu/hr N/A 25.9 kcal/h102.7 Btu/hr N/A 38.8 kcal/h154.1 Btu/hr N/A 45.4 kcal/h180.0 Btu/hr N/A 90.8 kcal/h360.0 Btu/hr
Burner Ignition Direct Current (DC) Voltage for Re-ignitor Standard on All Units N/A 9 V
Shipping Length N/A 21 in534 mm N/A 21 in534 mm N/A 21 in534 mm N/A 36 in915 mm N/A 43 in1092 mm
Shipping Height N/A 42 in1067 mm N/A 42 in1067 mm N/A 52 in1321 mm N/A 69 in1752 mm N/A 72 in1829 mm
Shipping Width N/A 22 in559 mm N/A 35 in889 mm N/A 35 in889 mm N/A 36 in915 mm N/A 48 in1219 mm
Shipping Weight N/A 170 lb78 kg N/A 250 lb113 kg N/A 275 lb125 kg N/A 450 lb205 kg N/A 1050 lb477 kg
Optional Accessories N/A
  • Economy Operation Kit
  • Filtaire for Heavy Ends
  • Relief Valve Pipe Away Adapter
  • Auto Ignition Kit-110VAC
  • 1 Maximum Allowable Working Pressure (MAWP)
  • 2 Vaporizer capacity shown as nominal. Actual capacity is affected by LPG composition and pressure.