Designed to reduce first stage pressure of 10 PSIG down to 2 PSIG. A line pressure regulator is required downstream to reduce the 2 PSIG to a nominal 11" w.c.

Unit of Measure
Items
LV4403Y Series 1/2 Inch (in) Inlet Connection Size and 1/2 Inch (in) Outlet Connection Size Second Stage Regulator for 2 Pounds Per Square Inch (PSI) Systems - (LV004403Y4)

LV4403Y Series 1/2" Inlet Connection Size and 1/2" Outlet Connection Size Second Stage Regulator for 2 PSI Systems
Price QUOTE

LV4403Y Series 1/2 Inch (in) Inlet Connection Size and 3/4 Inch (in) Outlet Connection Size Second Stage Regulator for 2 Pounds Per Square Inch (PSI) Systems - (LV004403Y46R)

LV4403Y Series 1/2" Inlet Connection Size and 3/4" Outlet Connection Size Second Stage Regulator for 2 PSI Systems
Price QUOTE

LV5503Y Series 3/4 Inch (in) Inlet Connection Size and 3/4 Inch (in) Outlet Connection Size Second Stage Regulator for 2 Pounds Per Square Inch (PSI) Systems - (LV005503Y6)

LV5503Y Series 3/4" Inlet Connection Size and 3/4" Outlet Connection Size Second Stage Regulator for 2 PSI Systems
Price QUOTE

LV5503Y Series 3/4 Inch (in) Inlet Connection Size and 1 Inch (in) Outlet Connection Size Second Stage Regulator for 2 Pounds Per Square Inch (PSI) Systems - (LV005503Y8)

LV5503Y Series 3/4" Inlet Connection Size and 1" Outlet Connection Size Second Stage Regulator for 2 PSI Systems
Price QUOTE
Description N/A

Second stage regulator for 2PSIG system. Designed to reduce first stage pressure of 10PSIG to 2PSIG. 1/2" F.NPT inlet. 1/2" F.NPT outlet. 1million BTU vapor capacity.

N/A

Second stage regulator for 2PSIG system. Designed to reduce first stage pressure of 10PSIG down to 2PSIG. 1/2" F.NPT inlet. 3/4" F.NPT outlet. 1million BTU vapor capacity.

N/A

Second stage regulator for 2PSIG system. 3/4" F.NPT inlet. 3/4" F.NPT outlet. 1million BTU vapor capacity.

N/A

Second stage regulator for 2PSIG system. 3/4" F.NPT inlet. 1" F.NPT outlet. 1million BTU vapor capacity.

Inlet Connection Size N/A 1/2 in N/A 1/2 in N/A 3/4 in N/A 3/4 in
Inlet Connection Type N/A Female National Pipe Thread (FNPT)
Outlet Connection Size N/A 1/2 in N/A 3/4 in N/A 3/4 in N/A 1 in
Outlet Connection Type N/A Female National Pipe Thread (FNPT)
Orifice Size N/A 1/4 in N/A 1/4 in N/A 1/4 in N/A 9/32 in
Factory Delivery Pressure at 10 Pounds Per Square Inch Gauge (psig) Inlet Pressure N/A 2 inWc
Pressure Adjustment Range N/A 1.6 to 2.2 psi
Bonnet Vent Position N/A Over Inlet
Propane Vapor Capacity N/A 1,000,000 Btu/hr N/A 1,000,000 Btu/hr N/A 2,200,000 Btu/hr N/A 2,200,000 Btu/hr
Capacity N/A 2 lb
Material N/A Die-Cast Zinc
Rating N/A Underwriters Laboratories (UL®) Listed
Note N/A

Maximum flow is based on 10 PSIG inlet pressure and 1.5 PSIG delivery pressure.