Unit of Measure
Items
65 Inch (in) Unit Length Second Sun Tank Heater

65 Inch (in) Unit Length Second Sun Tank Heater
Price QUOTE

25 Inch (in) Unit Length Second Sun Tank Heater (MODEL SS-10)

25 Inch (in) Unit Length Second Sun Tank Heater
Price QUOTE
Description N/A
Vaporization Type N/A No Flame (Catalytic Heater)
Start-Up Electrical Direct Current (DC) Voltage1 N/A 12 V
Operating Electrical2 N/A Self-Generated
Electrical Class N/A Hazardous Locations (Zone 1)
Environmental Range N/A -40 to 120 ºF-40 to 49 ºC
Fuel Type N/A Any Liquefied Petroleum Gas (LPG) Blend Butane Propane
Inlet Fuel Connection National Pipe Thread (NPT) Size N/A 1/4 in
Maximum Inlet Regulated Pressure N/A 10 to 11 inWc
Maximum Inlet Regulated Pressure (H20) N/A 254 to 279 mm
Maximum Inlet Unregulated Pressure N/A 10 to 250 psig0.7 to 17.2 barg
On/Off Activation Factory Settings N/A OFF at >80 PSIG (5.51 barg) ON at <70 PSIG (4.82 barg) Via Tank Pressure (Adjustable Set Point)
Heat Input N/A 30,000 Btu/hr7560 kcal/h N/A 10,000 Btu/hr2520 kcal/h
Added Vaporization to Tank at -20 Degree Fahrenheit (ºF) Temperature3 N/A 2.2 MMBtu/hour N/A 0.5 MMBtu/hour
Added Vaporization to Tank at -28 Degree Fahrenheit (ºF) Temperature4 N/A 550,000 kcal/h N/A 126,000 kcal/h
Mounts to (US Tank) N/A 1,000 to 12,000 gal3,785 to 45,425 L N/A 500 to 3,900 gal946 to 14,742 L
Tank Diameter N/A 41 to 84 in1,041 to 2,134 mm N/A 37 to 41 in940 to 1,041 mm
Unit Weight N/A 155 lb70 kg N/A 65 lb30 kg
Unit Length N/A 65 in1,651 mm N/A 25 in635 mm
Unit Width N/A 18.5 in470 mm
Unit Height N/A 9 in227 mm N/A 9 in228 mm
Shipping Weight N/A 175 lb75 kg N/A 70 lb32 kg
Shipping Length N/A 76 in1,931 mm N/A 32 in839 mm
Shipping Width N/A 26 in661 mm N/A 23 in585 mm
Shipping Height N/A 19 in483 mm N/A 20 in381 mm
Safety Monitoring (Per National Fire Protection Association (NFPA 58)) N/A Tank Pressure: >160 PSIG (11.03 barg) - OFF - Manual Restart Required

Tank Surface Temperature (2): >125 ºF (51.7 ºC)
Upper Sensor: Reverts to Standby Mode
Lower Sensor: OFF - Manual Restart Required

Below Minimum Pilot Temperature: OFF - Manual Restart Required
  • 1 Use vehicle battery and "jumper cables"
  • 2 Thermoelectric device creates voltage based on Delta T
  • 3 Second Sun adds vaporization capability to the ambient vaporization capability of the tank itself. Total vaporization becomes the sum of the "natural" + "added" vaporization.
  • 4 Second Sun adds vaporization capability to the ambient vaporization capability of the tank itself. Total vaporization becomes the sum of the "natural" + "added" vaporization.